ACR
Data
Loggers, Analysis Software
and Accessories

TECHNOLOGY
MADE TO MEASURE
ACR Systems Inc of Canada
are world renowned designers and manufacturers of Data Loggers that provide
accurate tools for Managers, Technicians, Scientists, Conservators, Building
consultants, when ever and where ever measurements need to be made and recorded.
ACR products are easy to use and comply with: ISO9001, CE, EN55011, FCC Class A,
IEC801-1, 2,3,4. Validation software for 21 CFR Part 11 Compliance.
Applications: Food process
Verification, Food Transportation, Transportation of temperature sensitive
goods, Equipment run time, HVAC system testing and balancing, Environmental
monitoring. Validation software that meets Food and Pharmaceutical requirements.
Click here to view the complete ACR
catalog
 |
SmartButton
-
-10ºC
to +85ºC Ambient and Measuring, accuracy ±0.5ºC (0 to 70ºC)
-
Size only 17mm
dia x 6mm high weight 4 grams
-
User selectable
sample rates from 1 to 255 minutes
-
8 bit resolution
2048 readings
-
User selectable
Alarm thresholds, event storage
-
Start delay,
event storage and user selectable alarm setting
-
10 year typical
battery life
| ORDER
CODES |
| ACR-SB |
SmartButton 17 mm dia x
6mm. Weight 4grams |
| ACR_SBSW |
Software free with starter pack |
|
 |
JR-1000/1.Temperature
Data Logger
-
-40ºC to +85ºC
Ambient and Measuring, accuracy ±0.2ºC (-40ºC to +85Cº)
-
Size only 33mm x
43mm x 20mm weight 35 grams
-
8000 User
selectable sample intervals. 32k memory with
compression
-
8 bit resolution
(1 part in 256)
-
Sample rates,
variable from 8 seconds to 34 minutes
-
5 year typical
battery life
-
I.S approved
JR-1001 UL for Class 1, Div 1, plus others.
| ORDER CODES |
| ACR-JR-1000 |
Logger 33 mm x 43mm.x 15mm Weight 29 grams |
| ACR-JR-1001 |
Intrinsic Safety version |
| TR-EXPRESS |
Free
Software and interface cable |
|
 |
TRH-1000
RH & Temperature Data Logger
-
Temperature
Measuring Range -40ºC to +70ºC, accuracy ±0.6ºC at 25ºC
-
R.H.
Measuring Range 0-100% RH, accuracy ±0.6% from 20% to 80% RH
-
32 KB User
selectable sample intervals
-
8 bit resolution
(1 part in 256)
-
Sample rates 8
seconds to 34 minutes
-
3 year typical
battery life
-
Supplied
complete with TR Express software and comms. cable
| ORDER CODES |
| TRH-1000 |
Size 25.4 mm
x 58.4mm x 81.3mm Weight 74 grams |
| TR-EXPRESS |
Free
Software and interface cable |
|
 |
Nautilus Waterproof data logger
-
-40ºC to +85ºC
Ambient and Measuring Range NTL-85
-
10ºC to +135ºC
Ambient and Measuring Range NTL-135
-
Size 18mm x 127mm
weight aluminium case 51 grams (112 grams S/S)
-
Operating pressure
up to 2000 PSI.
-
32KB memory.
Sample intervals 8 seconds to 34 minutes.
-
Resolution 0.4ºC
Sample rates 1 reading every 2 minutes
-
Battery life 3-10
years depending on model. Factory replaceable
| ORDER CODES |
| Nautilus
85A |
Aluminium
+85ºC sensor accuracy ±0.2ºC |
| Nautilus
85SS |
S/S
+85ºC sensor accuracy ±0.2ºC |
| Nautilus
135A |
Aluminium +135ºC sensor accuracy ±0.5ºC |
| Nautilus
135SS |
S/S +135ºC sensor accuracy ±0.5ºC |
| Software01-0275 |
Trendreader Express Complete interface package |
|
 |
SR-IAQ-100
Indoor Air Quality logger System
Measure and record
the three leading indicators of Indoor Air Quality: Temperature,
Relative Humidity and Carbon Dioxide. Helps resolve sick
building syndrome, building related illnesses and indoor air contaminants.
-
Five channels,
Internal Temperature, External RH and CO2 Sensor,
Plus two channels for optional remote RH and Temperature.
-
8 Bit resolution
32 KB memory,
-
CO2 Sensor by
Telair
| ORDER CODES |
| SR-IAQ |
Data Logger |
| IAQ-100 |
Telaire CO2
Monitor |
|
 |
OWL
data loggers
-
60mm x 48mm x
19mm 80gms potted, (54gms Noryl® plastic case)
-
8 bit resolution
(1 part in 256)
-
32KB Selectable
sample intervals from 5 per second to every 12 hours
-
40ºC to +70ºC
Ambient Measuring Range dependant on sensor selected
-
Optical data
transfer Alarm red LED
-
Full range of
accessories available
| ORDER CODES |
| Owl-100P |
Temperature Polyurethane encapsulated |
| Owl-100N |
Temperature
Noryl® plastic non water tight |
| Owl-200N |
Temperature external probe NTC thermistor |
| Owl-300N |
Electric current Sensors extra |
| Owl-400N |
DC Process signal Voltage |
| Owl-500N |
0-24 mA Process signal |
| TR-WIN-OWL |
OWL software interface wand, CD and manuals |
|
 |
8
bit SmartReader data loggers, SR series
-
107 x 74 22mm
weight 110 grams
-
8 bit (1 part in
256)
-
±0.2ºC
internal temperature sensor
-
-40ºC to +70ºC
Ambient temperature range
-
Optional remote
temperature sensors
-
Optional
additional RH/Temperature sensor
-
AC current
sensors options
-
Pressure sensors
to choice
-
Thermocouple
sensor inputs
-
Process Signal
input options
-
Pulse Rate/
Frequency measurement
-
Full range of
accessories available
| ORDER CODES |
| SR-001 |
2 channel
Temperature I internal 1 external |
| SR-002 |
4 channel
2 RH & Temp. 1 RH/Temp included |
| SR-003 |
4 channel AC current plus 1 Ambient Temp |
| SR-004 |
5 channel Pressure, Temperature and RH |
| SR-005 |
3 channel J.K.S.T t/c input Narrow and Wide span |
| SR-006N |
7 channel J.K.S.T t/c input Narrow span |
| SR-006W |
7 channel J.K.S.T t/c input Wide span |
| SR-007 |
8 channel Mixed Input ranges |
| SR-007 0-2.5V |
8 channel 0-2.5 volts DC input |
| SR-007 0-5V |
8 channel 0-5 volts DC input |
| SR-007 0-10V |
8 channel 0-10 Volts DC input |
| SR-007 25mA |
8 channel 0-25 mA input |
| SR-008 |
8 channel Temperature resistance, switch status |
| SR-009 |
3 channel Pulse Rate/Frequency |
| TR-WIN-SR |
TrendReader software/smart cable and manuals |
| RTM-WIN |
RealTime Graphing |
|
 |
12
bit SmartReader Plus data loggers SRP series
-
Resolution 12
bit (1 part in 4096), Memory options 128 KB or 1.5MB
-
Range of
external sensor options.
-
Inputs RH &
Temperature models
-
Thermistor or
Thermocouple input models.
-
AC Current &
Voltage models
-
Pressure with
built in sensor 0-10"W.C.
-
Pressure with
built in 0-150PSI A or G sensor
-
Low differential
pressure measurement
-
Process Signal
input Voltage or milli Amp
-
RTD sensor input
-
Pulse Rate &
Frequency input models
-
TalkBack
software option for auto downloading
-
Networking and
remote communications
-
Alarm Module add
on option
| ORDER CODES |
| SRP-001 |
2 channel
Temperature |
| SRP-002 |
4 channel 2 RH & Temp. 1
RH/Temp included
128KB memory standard |
| SRP-003 |
4 channel AC current plus 1 Ambient Temp. |
| SRP-004 |
5 channel Pressure, Temperature and RH in 32KB
or 128KB memory options only |
| SRP-4 LPD |
2 channel Low pressure differential 32KB
memory only |
| SRP-005 |
3 channel J.K.S.T.E t/c plus cold junction in
32KB or 128KB memory options |
| SRP-006N |
7 channel J.K.S.T.E t/c plus cold junction with
32KB 128KB or 1.5MB memory |
| SRP-007 |
8 channel 7
analogue DC volts, mV and mA Input
ranges all memory options |
| SRP-007 0-2.5V |
8 channel 7 analogue 0-2.5 volts DC input
32KB or 128KB memory |
| SRP-007 0-5V |
8 channel 7 analogue 0-5 volts DC input all
memory options |
| SRP-007 0-10V |
8 channel 7 analogue 0-10 Volts DC input
32KB or 128KB memory options |
| SRP-007 25mA |
8 channel 7 Process 0-25 mA input all
memory options |
| SRP-008 |
8 channel Temperature resistance, switch status
all memory options |
| SRP-009 |
2 channel Pulse Rate/Frequency 32KB or 128KB
memory options |
| TR-WIN-SRP |
TrendReader/Smart Reader Plus software pack
and smart cable and manuals |
| RTM-WIN |
TrendReader Real Time Graphing software |
| TBS-WIN |
TalkBack Alarm indication & Auto-Downloading
software |
|
JDL